[modeller_usage] W> MODEL atom not classified: GLY:OXT GLY
To:
Subject: [modeller_usage] W> MODEL atom not classified: GLY:OXT GLY
From: "Joaquim Rui Rodrigues" <>
Date: Wed, 24 Sep 2008 16:38:47 +0100
Dear Modellers,
I am trying to build some missing loops in a PDB structure with modeller 9v4. For this, I am using the script found
in examples/automodel/model-loop-define.py for which I only changed residue_range's, and alnfile, knowns and
sequence. The protein is a dimer, and both subunits end with a Gly residue.
I am getting this warning at the DOPE potential assessment:
>> Model assessment by DOPE potential
iatmcls_286W> MODEL atom not classified: GLY:OXT GLY
iatmcls_286W> MODEL atom not classified: GLY:OXT GLY
A related message in the archives suggests editing modlib/atmcls-melo.lib (http://www.salilab.org/archives/
modeller_usage/2004/msg00169.html). This file seems to be used for loop modelling, but not for DOPE
evaluation, as suggested in the log file:
openf___224_> Open ${LIB}/atmcls-mf
I have also tried to use the dope_loopmodel class, instead of loopmodel. Here, I get the same warnings for both
stages (loop modelling and DOPE assessment).
How can I avoid such messages? Should I somehow edit atmcls-mf.lib?
Many thanks,
Rui Rodrigues
--
Webmail ESTG de Leiria (http://webmail.estg.ipleiria.pt)