[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[modeller_usage] Using Clustal alignment



Hello,
 
I have a problem trying to use external alignment (from Clustal Omega, converted to PIR format).
However, Modeller refuses to read the PDB template. After several rounds of iterative correction, I specified only the residues and numbers actually present in the PDB file in alignment:
>P1;5u09A
structure:5u09A: 100 :A:+478 :A::::
---------- ---------- ---------- ---------- ----------
---------- ---------- ---------- ---------- ---------E
NFMDIECFMV LNPSQQLAIA VLSLTLGTFT VLENLLVLCV ILHSRSLRCR
But I get the following error:
read_te_291E> Sequence difference between alignment and  pdb :
                  x  (mismatch at alignment position     11)
Alignment   .....E.NFMDIECFMV.LNPSQQLAIA.VLSLTLGTFT.VLENLLVLCV.ILHSRSLRC
       PDB   IECFMVLNPSQQLAIAVLSLTLGTFTVLENLLVLCVILHSRSLRCRPSYHFIGSLAVADL
     Match   ***** **        **          * *        *          **
  Alignment residue type    4 (E, GLU) does not match pdb
  residue type   18 (V, VAL),
  for align code 5u09A (atom file 5u09A), pdb residue number "110", chain "A"
That is, it somehow skips the first 5 residues from the PDB but adds 5 dots to the alignment sequence, and then (unsurprisingly) everything breaks =(
What is wrong?
 
Thank you in advance
Eugene