Re: [modeller_usage] more sequence difference issues
To: Irene Newhouse <>
Subject: Re: [modeller_usage] more sequence difference issues
From: Modeller Caretaker <>
Date: Thu, 18 Nov 2010 14:21:25 -0800
Cc:
On 11/18/10 12:54 PM, Irene Newhouse wrote:
In the interests of appearing to make progress, I dropped the alignment
of which I wrote an hour or so ago from the mulitple alignments
considered. Now I have another sequence difference issue with 1x06.pdb.
Robert's answer is spot on. Modeller only deals with structural
information from templates, so it reads the PDB sequence from the
ATOM/HETATM records, not SEQRES, and that's the sequence that needs to
match your alignment file.